Your browser doesn't support javascript.
loading
Nano-scale multi-spectroscopic analysis of the anti-fibromyalgia drug pregabalin based on dihydropyridine ring formation with sustainability and whiteness evaluation.
El Hamd, Mohamed A; Obaydo, Reem H; Ibrahim Helmy, Marwa; Mahdi, Wael A; Alshehri, Sultan; El-Maghrabey, Mahmoud; Nessim, Christine K.
Affiliation
  • El Hamd MA; Department of Pharmaceutical Chemistry, College of Pharmacy, Shaqra University, Shaqra 11961, Saudi Arabia; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, South Valley University, Qena 83523, Egypt. Electronic address: aboelhamdmohamed@su.edu.sa.
  • Obaydo RH; Department of Analytical and Food Chemistry, Faculty of Pharmacy, Ebla Private University, Idlib, Syria.
  • Ibrahim Helmy M; Department of Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan, Egypt.
  • Mahdi WA; Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
  • Alshehri S; Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
  • El-Maghrabey M; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, 35516 Mansoura, Egypt. Electronic address: dr_m_hamed@mans.edu.eg.
  • Nessim CK; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Ahram Canadian University, 12566, 6(th) October, Cairo, Egypt.
Spectrochim Acta A Mol Biomol Spectrosc ; 325: 125151, 2024 Sep 17.
Article in En | MEDLINE | ID: mdl-39316853
ABSTRACT
This research addresses the challenge of analyzing pregabalin, a primary amine in a zwitterionic structure, which is difficult to evaluate due to its lack of chromatophore. The study introduces a derivatization assessment using Hantzsch's multicomponent organic reaction to enhance the detectability of pregabalin by forming a highly fluorescent dihydropyridine derivative. This process involves the condensation of pregabalin with acetylacetone and formaldehyde, yielding a yellowish-green compound measurable both colorimetrically at 338 nm and fluorimetrically at an emission wavelength of 486 nm (λexcitation = 408 nm). The reaction conditions were thoroughly optimized to obtain the highest possible sensitivity, reduce reagent and time consumption, and use safe solvents. The developed method displayed high sensitivity and linearity in the concentration ranges of 4.0 - 20.0 µg/mL in colorimetric assay and reached a nano-scale analysis level of 40 - 2000 ng/mL with a detection limit down to 10 ng/mL when adopting the fluorimetric measurement. Both assessments were rigorously evaluated for their performance, adhering to the International Conference on Harmonization (ICH) standards. The accuracy of these methods was confirmed through the recovery rates of real samples, showing 98.9 ± 0.2 % for colorimetric and 98.2 ± 0.7 % for fluorimetric assessment. The excellent sensitivity of the suggested spectrofluorometric approach led to its use in the measurement of PRG in spiked human urine samples, resulting in particularly good recoveries ranging from 95.3 to 102.8 %. Meanwhile, the Need, Quality, Sustainability (NQS) index looks into how necessary the method is, execution quality (evaluated using the RGB 12 algorithm), and how it fits with the Sustainable Development Goals (SDGs), underlining the benefits of employing natural reagents. The developed approach showed superiority in sensitivity and sustainability compared to previous analytical approaches for pregabalin.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Spectrochim Acta A Mol Biomol Spectrosc Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Spectrochim Acta A Mol Biomol Spectrosc Year: 2024 Document type: Article