Quantitative assessment of silicone oil release with siliconized and silicone oil-free syringes by microflow imaging microscopy / Avaliação quantitativa da liberação de óleo de silicone por seringas siliconizadas e sem óleo de silicone usando microflow imaging microscopy
Agra, Lydianne Lumack do Monte; Cruz, Natasha Ferreira Santos da; Linkuviene, Vaida; Carpenter, John F.; Farah, Michel Eid; Melo, Gustavo Barreto; Maia, Maurício.
Afiliação
  • Agra, Lydianne Lumack do Monte; Hospital de Olhos de Sergipe. Aracaju. BR
  • Cruz, Natasha Ferreira Santos da; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology. São Paulo. BR
  • Linkuviene, Vaida; University of Colorado. Department of Pharmaceutical Sciences. Anschutz Medical Campus. US
  • Carpenter, John F.; University of Colorado. Department of Pharmaceutical Sciences. Anschutz Medical Campus. US
  • Farah, Michel Eid; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology. São Paulo. BR
  • Melo, Gustavo Barreto; Hospital de Olhos de Sergipe. Aracaju. BR
  • Maia, Maurício; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology. São Paulo. BR
Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520198
Biblioteca responsável: BR1.1
ABSTRACT
ABSTRACT Purpose: Since particles are released in syringes during intravitreal injections, we assessed them quantitatively after agitating syringes commonly used for intravitreal injections. Methods: With and without agitation, the SR 1-ml insulin, Becton-Dickinson Ultra-Fine 0.3-ml Short Needle with a half-unit scale, HSW Norm-Ject Tuberculin, and Becton-Di­ckinson 1-ml Luer Lok Tip were examined with buffer and bevacizumab, aflibercept, and ziv-aflibercept. Flow imaging microscopy was performed to assess the particle numbers, concentrations, morphology, and size distribution. Results: Using the Becton-Dickinson Ultra-Fine syringe, the average particle count after agitation was higher than in the no-agitation group. For particles greater than 10 and 25 µm, differences were observed using the SR syringe between the two studied conditions. There were no significant differences in the means for the other syringes. Without agitation, the SR syringe had the highest number of particles (2,417,361.7 ± 3,421,575.5) followed by the Becton-Dickinson Ultra-Fine with 812.530,9 ± 996.187,2. The Becton-Dickinson Luer Lok Tip and HSW Norm-Ject performed equally with 398,396.8 ± 484,239.2 and 416,016.4 ± 242,650.1 particles, respectively. Conclusions: Flicking syringes to eliminate air bubbles results in increased numbers of particles released during intravitreal injections into the human vitreous.
RESUMO
RESUMO Objetivo: Visto que partículas são liberadas nas seringas durante as injeções intravítreas (IVIs), estas foram avaliadas quantitativamente após a agitação das seringas mais comumente usadas para injeções intravítreas. Métodos: A seringa SR de 1 ml de insulina, a agulha curta Becton-Dickinson Ultra-Fine 0,3 ml com escala de meia unidade, HSW Norm-Ject Tuberculin e a Becton-Dickinson Luer Lok Tip de 1 ml foram estudadas com placedo e com bevacizumabe, aflibercept e ziv-aflibercept, com e sem agitação. MicroFlow Imaging Mi­croscopy foi realizada para avaliar o número de partículas, con­centração, morfologia e distribuição das mesmas por tamanho. Resultados: A contagem média de partículas após agitação foi maior do que no grupo sem agitação usando a seringa Becton-Di­ckinson Ultra-Fine. Diferenças foram observadas usando a seringa SR entre as duas condições estudadas para partículas maiores que 10 e 25 µm. Para as demais seringas, não foram observadas diferenças significativas nas médias. A seringa SR apresentou o maior número de partículas sem agitação (2.417.361,7 ± 3.421.575,5) seguida da Becton-Dickinson Ultra-Fine com 812.530,9 ± 996.187,2. A BD Luer Lok Tip e a HSW Norm-Ject se comportaram de forma semelhante com 398.396,8 ± 484.239,2 e 416.016,4 ± 242.650,1 partículas, respectivamente. Conclusões: Agitar seringas para remover bolhas de ar resulta em um maior número de partículas liberadas durante Becton-Dickinson no vítreo humano.