Elaboração e implementação de um programa para verificação dos cálculos das unidades monitoras em radioterapia / Development and implementation of a software for assessment of calculations in radiotherapy monitor units
Müller, Márcio Rogério; Rodrigues, Laura Natal; Silva, Marco Antônio da.
Afiliação
  • Müller, Márcio Rogério; Universidade de São Paulo. Instituto de Pesquisas Energéticas e Nucleares. São Paulo. BR
  • Rodrigues, Laura Natal; Universidade Federal do Rio de Janeiro. Rio de Janeiro. BR
  • Silva, Marco Antônio da; Universidade de São Paulo. Instituto de Pesquisas Energéticas e Nucleares. São Paulo. BR
Radiol. bras ; 38(6): 415-420, nov.-dez. 2005. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-421244
Biblioteca responsável: BR734.1
RESUMO

OBJETIVO:

Desenvolvimento e implementação de um programa, fundamentado no algoritmo de cálculo manual, para verificação dos cálculos de unidades monitoras em radioterapia e estabelecimento de patamares de aceitação, como mecanismo de garantia da qualidade.

MATERIAIS E MÉTODOS:

Os dados apresentados foram obtidos a partir dos aceleradores lineares modelo Clinac 600C e 2100C, da Varian, e o sistema de planejamento de tratamento computadorizado utilizado foi o CadPlanÕ.

RESULTADOS:

Para os feixes de 6 MV os patamares de aceitação para desvios entre os cálculos de unidades monitoras, separados por região de tratamento, foram mama (0,0 por cento ± 1,7 por cento), cabeça e pescoço (1,5 por cento ± 0,5 por cento), hipófise (-1,7 por cento ± 0,5 por cento), pelve (2,1 por cento ± 2,1 por cento) e tórax (0,2 por cento ± 1,3 por cento). Para os feixes de 15 MV, o patamar sugerido para pelve em todas as técnicas de tratamento foi de (3,2 por cento ± 1,3 por cento).

CONCLUSÃO:

Os dados são suficientes para justificar seu uso na prática clínica como ferramenta no programa de garantia da qualidade.
ABSTRACT

OBJECTIVE:

To develop and implement a software based on the manual calculation algorithm for verification of the calculations in radiotherapy monitor units and to establish acceptance levels as a mechanism of quality assurance. MATERIALS AND

METHODS:

Data were obtained from Clinac 600C and 2100C Varian linear accelerators and the computerized treatment planning system used was CadPlan™.

RESULTS:

For the 6 MV beams the acceptance levels for deviations among the calculations of monitor units, divided by treatment area, were the following breast (0.0% ± 1.7%), head and neck (1.5% ± 0.5%), hypophysis (–1.7% ± 0.5%), pelvis (2.1% ± 2.1%) and thorax (0.2% ± 1.3%). For the 15 MV beams the suggested level for pelvis in all the treatment techniques was (3.2% ± 1.3%).

CONCLUSION:

The present data are sufficient to justify the use of the software in the clinical practice as a tool for the quality assurance program.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Base de dados: LILACS Assunto principal: Radioterapia / Algoritmos / Monitoramento de Radiação / Monitoramento Ambiental / Planejamento Tipo de estudo: Guia de prática clínica / Revisão sistemática de estudos observacionais Aspecto: Pesquisa de implementação Idioma: Português Revista: Radiol. bras Ano de publicação: 2005 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: ODS3 - Saúde e Bem-Estar Base de dados: LILACS Assunto principal: Radioterapia / Algoritmos / Monitoramento de Radiação / Monitoramento Ambiental / Planejamento Tipo de estudo: Guia de prática clínica / Revisão sistemática de estudos observacionais Aspecto: Pesquisa de implementação Idioma: Português Revista: Radiol. bras Ano de publicação: 2005 Tipo de documento: Artigo