Your browser doesn't support javascript.
loading
Computerized invasive measurement of time-dependent intraocular pressure
Campos, T. V. O; Jacobovitz, S; Almeida, H. G; Massensini, A. R; Moraes, M. F. D.
Afiliação
  • Campos, T. V. O; Universidade Federal de Minas Gerais. Instituto de Ciências Biológicas. Departamento de Fisiologia e Biofísica. Núcleo de Neurociências. Belo Horizonte. BR
  • Jacobovitz, S; Universidade Federal de Minas Gerais. Hospital São Geraldo. Departamento de Oftalmologia. Belo Horizonte. BR
  • Almeida, H. G; Universidade Federal de Minas Gerais. Hospital São Geraldo. Departamento de Oftalmologia. Belo Horizonte. BR
  • Massensini, A. R; Universidade Federal de Minas Gerais. Instituto de Ciências Biológicas. Departamento de Fisiologia e Biofísica. Núcleo de Neurociências. Belo Horizonte. BR
  • Moraes, M. F. D; Universidade Federal de Minas Gerais. Instituto de Ciências Biológicas. Departamento de Fisiologia e Biofísica. Núcleo de Neurociências. Belo Horizonte. BR
Braz. j. med. biol. res ; 39(9): 1249-1253, Sept. 2006. ilus
Artigo em Inglês | LILACS | ID: lil-435429
Biblioteca responsável: BR1.1
ABSTRACT
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Transdutores de Pressão / Processamento de Sinais Assistido por Computador / Pressão Intraocular Tipo de estudo: Estudo diagnóstico / Guia de prática clínica Limite: Animais Idioma: Inglês Revista: Braz. j. med. biol. res Ano de publicação: 2006 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Transdutores de Pressão / Processamento de Sinais Assistido por Computador / Pressão Intraocular Tipo de estudo: Estudo diagnóstico / Guia de prática clínica Limite: Animais Idioma: Inglês Revista: Braz. j. med. biol. res Ano de publicação: 2006 Tipo de documento: Artigo