Vo2max estimadoppor equações preditivas apresena baixa concordância com o obtiido pelo teste cardiopulmonar - padrão ouro / Vo2maxestimated by predictive equatios presents low concordance withh that obtained by cardiopulmonary test - gold standard
Rev. educ. fis
; 26(1): 131-145, jan.-mar. 2015. tab, ilus
Article
em Pt
| LILACS
| ID: lil-759479
Biblioteca responsável:
BR1.1
RESUMO
RESUMOO objetivo foi avaliar a concordância entre mensurações do VO2maxobtidas em teste cardiopulmonar de exercício versus obtidas por equações preditivas. Homens (21-55 anos) foram agrupados em praticantes de musculação (PM; n=31) e corridas (PC; n=28) e não praticantes (SE; n=35). Testou-se 5 equações, uma delas elaborada a partir de amostra brasileira. A concordância foi avaliada por Bland-Altman e as correlações pelo coeficiente de correlação de Pearson (r). Os r entre medida padrão ouro vs. equações ficaram entre 0,27 a 0,75, com p<0,05 para a maioria. Entretanto, as concordâncias foram baixas. Na equação obtida em brasileiros, os valores menos concordantes foram, em ordem SE, PM e PC; nas demais equações foram PC, PM e SE. As piores estimativas foram para VO2maxmais elevados, principalmente >40 mL.kg-1.min1. Conclui-se que as equações preditivas avaliadas nesse estudo geraram medidas de baixa concordância quando comparadas ao padrão ouro, principalmente para VO2max>40 mL.kg-1.min-1.
ABSTRACT
ABSTRACTThe aim was to evaluate the concordance between measurements of VO2max obtained by exercise cardiopulmonary test (gold-standard) vs. that obtained by predictive equations. Men (21-55 years-old) were grouped into Resistance training (RT; n=31), long-distance runners (R; n=28) and non-exercise practitioners (C; n=35). Five equations were tested, one of them made from Brazilian sample. The concordance was evaluated by Bland-Altman, and correlation analysis by Pearson's coefficient (r). The r between gold-standard vs. equations ranged 0.27 to 0.75, with p<0.05 for the most analysis, however, with low concordance. Regarding the equation obtained in Brazilians, the values with lower concordance were, following the order C, RT and R. In relation to others equations, again with lower concordance, the order was R, RT and C. The worst estimates were to higher VO2max values, mainly for >40 mL.kg-1.min-1. In conclusion, the predictive equations tested generate low concordance when compared to VO2maxgold-standard test, mainly for VO2max>40 mL.kg-1.min-1.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Tipo de estudo:
Prognostic_studies
/
Risk_factors_studies
Idioma:
Pt
Revista:
Rev. educ. fis
Ano de publicação:
2015
Tipo de documento:
Article