The nuclide 110Ag is a beta-gamma emitter with a very complex decay scheme, including more than 50 gamma-rays. It has been standardized by two methods:
liquid scintillation counting (LSC) and 4pibeta(pc)-gamma coincidence measurements. In the LSC measurements the CIEMAT/NIST method was used, with 3H being used as a tracer for efficiency calculations. In the 4pibeta(pc)-gamma standardization, Monte Carlo calculations have been made to determine the optimal measurement conditions. Results obtained with both methods for the activity concentration of the solution are in good agreement.