[Is transvenous cardiac pacemaker implantation with X-ray control associated with a dangerous radiation exposure? (author's transl)]. / Führt die transvenöse Herzschrittmacherimplantation unter Röntgenbildkontrolle zu einer gefährlichen Strahlenbelastung
Thoraxchir Vask Chir
; 23(5): 511-3, 1975 Oct.
Article
em De
| MEDLINE
| ID: mdl-1081775
From July to December 1974 we measured the radiation exposure of the hands of the operator and assistant with 69 implantations of permanent cardiac pacemakers and recorded a dose of 0,5 mrem/min, this corresponds to 4 mrem/patient.