Stimulated acoustic emission: pseudo-Doppler shifts seen during the destruction of nonmoving microbubbles.
Tiemann, K; Pohl, C; Schlosser, T; Goenechea, J; Bruce, M; Veltmann, C; Kuntz, S; Bangard, M; Becher, H.
Afiliação
  • Tiemann K; Department of Cardiology, University of Bonn, Bonn, Germany. k-tiemann@Uni-Bonn.de
Ultrasound Med Biol ; 26(7): 1161-7, 2000 Sep.
Article em En | MEDLINE | ID: mdl-11053751
ABSTRACT
The purpose of this study was to evaluate the appearance and the characteristics of stimulated acoustic emission (SAE) as an echo contrast-specific color Doppler phenomenon with impact on myocardial contrast echocardiography (MCE). Stationary microbubbles of the new contrast agent SH-U 563A (Schering AG) were embedded within a tissue-mimicking gel material. Harmonic power Doppler imaging (H-PDI), color Doppler and pulse-wave Doppler data were acquired using an HDI-5000 equipped with a phased-array transducer (1.67/3.3 MHz). In color Doppler mode, bubble destruction resulted in random noise like Doppler signals. PW-Doppler revealed short "pseudo-Doppler" shifts with a broadband frequency spectrum. Quantification of SAE events by H-PDI demonstrated an exponential decay of signal intensities over successive frames. A strong linear relationship was found between bubble concentration and the square root of the linearized H-PDI signal for a range of concentrations of more than two orders of magnitude (R = 0.993, p < 0.0001). Intensity of the H-PDI signals correlated well with emission power (R = 0.96, p = 0.0014). SAE results from disintegration of microbubbles and can be demonstrated by all Doppler imaging modalities, including H-PDI. Intensity of SAE signals is influenced by the applied acoustic power and correlates highly with the concentration of microbubbles. Because intensity of SAE signals correlates highly with echo contrast concentrations, analysis of SAE signals might be used for quantitative MCE.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia Doppler em Cores / Meios de Contraste / Embucrilato Tipo de estudo: Evaluation_studies Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2000 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia Doppler em Cores / Meios de Contraste / Embucrilato Tipo de estudo: Evaluation_studies Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2000 Tipo de documento: Article