Microwave coagulation therapy with interruption of hepatic blood in- or outflow: an experimental study.
Takamura, M; Murakami, T; Shibata, T; Ishida, T; Niinobu, T; Kawata, S; Shimizu, J; Kim, T; Monden, M; Nakamura, H.
Afiliação
  • Takamura M; Department of Radiology, Osaka University Medical School, Suita City, Osaka, Japan. takamura@radiol.med.osaka-u.ac.jp
J Vasc Interv Radiol ; 12(5): 619-22, 2001 May.
Article em En | MEDLINE | ID: mdl-11340142
ABSTRACT

PURPOSE:

To determine how interruption of hepatic blood in- or outflow affects the coagulation diameter of microwave coagulation therapy (MCT) in the liver. MATERIALS AND

METHODS:

Laparotomic MCT at 60 W for 1 minute was performed in 11 Landrace pigs. MCT was performed under six different conditions without occlusion (Group N; in seven lobes of seven pigs); with occlusion of the hepatic artery (Group A; in five lobes of five pigs); with occlusion of the portal vein (Group P; in five lobes of five pigs); with occlusion of the hepatic artery and portal vein (Group AP; in six lobes of six pigs); with occlusion of the hepatic vein (Group V; in five lobes of four pigs); and with occlusion of the hepatic artery and vein (Group AV; in seven lobes of seven pigs). The maximum diameters for each group were compared.

RESULTS:

The coagulation diameters (mean +/- SD) were 8.5 mm +/- 2.0, 10.0 mm +/- 1.6, 14.3 mm +/- 2.5, 14.4 mm +/- 2.4, 13.0 mm +/- 0.8, and 14.4 mm +/- 1.5 for Groups N, A, P, AP, V, and AV, respectively. The coagulation diameters for groups P, AP, V, and AV were statistically larger than those for groups N and A (P < .05). There was no significant difference between the coagulation diameters of Groups P, AP, V, and AV.

CONCLUSION:

The coagulation diameter depends mainly on the portal venous flow. In addition of direct interruption of the portal vein, interruption of the hepatic vein can also result in a substantial increase in the coagulation diameter.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocoagulação / Fígado / Circulação Hepática / Micro-Ondas Limite: Animals Idioma: En Revista: J Vasc Interv Radiol Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocoagulação / Fígado / Circulação Hepática / Micro-Ondas Limite: Animals Idioma: En Revista: J Vasc Interv Radiol Ano de publicação: 2001 Tipo de documento: Article