Your browser doesn't support javascript.
loading
Determination of clenbuterol in bovine liver by combining matrix solid-phase dispersion and molecular imprinted solid-phase extraction followed by liquid chromatography/electrospray ion trap multiple-stage mass spectrometry.
Crescenzi, C; Bayoudh, S; Cormack, P A; Klein, T; Ensing, K.
Afiliação
  • Crescenzi C; Department of Analytical Chemistry and Toxicology, University Center for Pharmacy, Groningen, The Netherlands. carlo.crescenzi@anchem.su.se
Anal Chem ; 73(10): 2171-7, 2001 May 15.
Article em En | MEDLINE | ID: mdl-11393837
Matrix solid-phase dispersion (MSPD) is a new sample pretreatment for solid samples. This technique greatly simplifies sample pretreatment but, nonetheless, the extracts often still require an extra cleanup step that is both laborious and time-consuming. The potential of combining MSPD with molecularly imprinted solid-phase extraction (MISPE) was investigated in this study. Liver samples were ground in a mortar with C18 sorbent and the homogenized mixture packed into an SPE cartridge and placed on top of a MISPE cartridge. Subsequently, clenbuterol was eluted from the MSPD cartridge onto the MISPE cartridge using acetonitrile containing 1% acetic acid. The ability of the molecularly imprinted polymer to selectively adsorb analyte in acetonitrile was exploited for re-extracting clenbuterol directly from this acetonitrile extract via the double cartridge tandem system. The analyte was eluted from the MISPE cartridge using acidified methanol. A clear eluate was obtained, which was subsequently evaporated, redissolved, and analyzed by HPLC electrochemical detection (ECD) or ion trap mass spectrometry (LC/IT-MS). The MISPE cartridge used in this study was imprinted using bromoclenbuterol, a structural analogue of clenbuterol, as the template. These MISPE cartridges showed excellent stability. The complete extraction procedure was rapid, and recoveries exceeded 90% for the target analyte. The method detection limit for the LC/IT-MS procedure was < 0.1 microg/kg. This method, therefore, satisfies the stringent requirements of European Union regulation EEC 2377/90.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Clembuterol / Agonistas Adrenérgicos beta / Espectrometria de Massas por Ionização por Electrospray / Fígado Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Clembuterol / Agonistas Adrenérgicos beta / Espectrometria de Massas por Ionização por Electrospray / Fígado Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2001 Tipo de documento: Article