Dynamic laryngotracheal closure for aspiration: a preliminary report.
Broniatowski, M; Grundfest-Broniatowski, S; Tyler, D J; Scolieri, P; Abbass, F; Tucker, H M; Brodsky, S.
Afiliação
  • Broniatowski M; Department of Surgery Otolaryngology-Head and Neck Surgery, St. Vincent Charity Hospital, University Hospital Health System, Ohio, USA.
Laryngoscope ; 111(11 Pt 1): 2032-40, 2001 Nov.
Article em En | MEDLINE | ID: mdl-11801992
ABSTRACT
OBJECTIVES/

HYPOTHESIS:

An estimated 500,000 patients per year in the United States. are affected by stroke-related dysphagia. Approximately half experience aspiration, which can lead to pneumonia or death. Aspiration may result from many factors, including delayed transport of the bolus, faulty laryngeal elevation, and poor coordination or inappropriate timing of vocal cord closure. Interventions carried out to protect the lungs are usually irreversible, destructive to the upper airway, and rarely prevent the need for enteral tube feeding. STUDY

DESIGN:

We present a report of the first implantations of a new device in an FDA-approved study to restore dynamic laryngotracheal separation. Two stroke patients needing tracheostomy were selected based on chronic aspiration verified by clinical and radiologic criteria (modified barium swallow [MBS]).

METHODS:

The left recurrent laryngeal nerve was exposed and electrically stimulated to verify vocal fold adduction. Huntington Medical Research Institute Bipolar Helical Electrodes were then implanted around the nerve. The leads were tunneled and linked to a NeuroControl Implantable Receiver-Stimulator placed subcutaneously on the chest wall. Activation of the stimulator was performed through an external transmitter linked by induction.

RESULTS:

The device was successfully triggered intra- and postoperatively. Serial flexible fiberoptic endoscopies and MBS demonstrate that aspiration is systematically arrested using low levels of electrical stimulation (42 Hz, 48-100 microsec, 1 mA).

DISCUSSION:

This pioneering work has shown that aspiration can be controlled without airway damage for a wide population of neurologically impaired patients because it appears more physiological than standard therapies.

CONCLUSION:

Based on the first two patients, paced laryngotracheal separation is clinically effective in controlling aspiration.
Assuntos
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 4_TD / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Pneumonia Aspirativa / Nervo Laríngeo Recorrente / Traqueia / Transtornos de Deglutição / Terapia por Estimulação Elétrica / Acidente Vascular Cerebral / Laringe Tipo de estudo: Etiology_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Laryngoscope Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 4_TD / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Pneumonia Aspirativa / Nervo Laríngeo Recorrente / Traqueia / Transtornos de Deglutição / Terapia por Estimulação Elétrica / Acidente Vascular Cerebral / Laringe Tipo de estudo: Etiology_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Laryngoscope Ano de publicação: 2001 Tipo de documento: Article