Your browser doesn't support javascript.
loading
Steady-state and transient-state performance of a biotrickling filter treating chlorobenzene-containing waste gas.
Seignez, C; Adler, N; Thoeni, C; Stettler, M; Péringer, P; Holliger, C.
Afiliação
  • Seignez C; ENAC-Laboratory for Environmental Biotechnology, Swiss Federal Institute of Technology Lausanne (EPFL), Bâtiment CH-B Ecublens, 1015 Lausanne, Switzerland. chantal.seignez@epfl.ch
Appl Microbiol Biotechnol ; 65(1): 33-7, 2004 Jul.
Article em En | MEDLINE | ID: mdl-14727094
ABSTRACT
Biotrickling filter (BTF) technology was applied for the treatment of waste gas containing a mixture of chlorobenzene and 1,2-dichlorobenzene. An adapted microbial community was immobilised on a structured packing material. The strategy followed was to reach high removal efficiencies at initially low mass loading rates followed by an increase of the latter. This procedure was successful and resulted in a short start-up period of only 2 weeks. A 3-month operation under steady-state conditions showed good performance, with >95% removal efficiency at a mass loading rate of 1,800 g m(-3) day(-1). Dimensionless concentration profiles showed that the chlorobenzenes were simultaneously degraded. Low dissolved organic carbon of 15 mg l(-1) and stoichiometric chloride concentrations in the trickling liquid indicated complete mineralisation of the pollutant. Transient-state experiments with five times higher mass loading rates caused a decrease in the removal efficiency that recovered rapidly once the mass loading rate returned to its original steady-state level. A progressive increase of the mass loading rate in a long-term performance experiment showed that the removal efficiency could be kept stable between 95 and 99% at loads of up to 5,200 g m(-3) day(-1) over several days. Above this mass loading rate, the elimination capacity did not increase any further. These results demonstrated that with a well-adapted inoculum and optimal operation parameters, a BTF system with excellent performance and stability that efficiently removes a mixture of chlorobenzene vapours from air can be obtained.
Assuntos
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Bactérias / Clorobenzenos / Poluentes Atmosféricos / Filtração Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Bactérias / Clorobenzenos / Poluentes Atmosféricos / Filtração Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2004 Tipo de documento: Article