Your browser doesn't support javascript.
loading
High-throughput microfluidic mixing and multiparametric cell sorting for bioactive compound screening.
Young, Susan M; Curry, Mark S; Ransom, John T; Ballesteros, Juan A; Prossnitz, Eric R; Sklar, Larry A; Edwards, Bruce S.
Afiliação
  • Young SM; Cytometry, Cancer Research and Treatment Center, University of New Mexico Health Sciences Center, Albuquerque, USA.
J Biomol Screen ; 9(2): 103-11, 2004 Mar.
Article em En | MEDLINE | ID: mdl-15006133
ABSTRACT
HyperCyt, an automated sample handling system for flow cytometry that uses air bubbles to separate samples sequentially introduced from multiwell plates by an autosampler. In a previously documented HyperCyt configuration, air bubble separated compounds in one sample line and a continuous stream of cells in another are mixed in-line for serial flow cytometric cell response analysis. To expand capabilities for high-throughput bioactive compound screening, the authors investigated using this system configuration in combination with automated cell sorting. Peptide ligands were sampled from a 96-well plate, mixed in-line with fluo-4-loaded, formyl peptide receptor-transfected U937 cells, and screened at a rate of 3 peptide reactions per minute with approximately 10,000 cells analyzed per reaction. Cell Ca(2+) responses were detected to as little as 10(-11) M peptide with no detectable carryover between samples at up to 10(-7) M peptide. After expansion in culture, cells sort-purified from the 10% highest responders exhibited enhanced sensitivity and more sustained responses to peptide. Thus, a highly responsive cell subset was isolated under high-throughput mixing and sorting conditions in which response detection capability spanned a 1000-fold range of peptide concentration. With single-cell readout systems for protein expression libraries, this technology offers the promise of screening millions of discrete compound interactions per day.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Citometria de Fluxo Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Biomol Screen Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Citometria de Fluxo Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Idioma: En Revista: J Biomol Screen Ano de publicação: 2004 Tipo de documento: Article