Three-dimensional finite element stress analysis of a cantilever fixed partial denture.
J Prosthet Dent
; 68(2): 243-8, 1992 Aug.
Article
em En
| MEDLINE
| ID: mdl-1501167
A three-dimensional mathematical model was generated, representing a three-unit cantilever fixed partial denture and its supporting mandibular structures. First and second premolars were used as abutments with one posterior cantilever pontic. A 5 lb vertical load was applied to the pontic. Vertical and horizontal stresses were analyzed by means of a three-dimensional finite element stress analysis technique. The results showed that a cantilever pontic creates considerable compressive stress on the abutment nearest to the pontic and produces tensile stress on the abutment farthest from the pontic.