Characterisation of the TAPIRO BNCT thermal facility.
Rosi, G; Gambarini, G; Colli, V; Gay, S; Scolari, L; Fiorani, O; Perrone, A; Nava, E; Fasolo, F; Visca, L; Zanini, A.
Afiliação
  • Rosi G; ENEA FIS-ION, CR Casaccia, via Anguillarese 301, I-00060 Roma, Italy. giancarlo.rosi@casaccia.enea.it
Radiat Prot Dosimetry ; 110(1-4): 651-4, 2004.
Article em En | MEDLINE | ID: mdl-15353725
ABSTRACT
Dosimetry and spectrometry measurements have been carried out in the thermal column of the research fast reactor RSV-TAPIRO (ENEA-Casaccia, Rome) in order to investigate its suitability for irradiation of cells or mice, with a view to research in the interests of boron neutron capture therapy (BNCT). The thermal column consists of a graphite moderator (40 cm thick) containing a lead shield (13 cm thick) in order to shield reactor background. The irradiation volume, inside this structure, has cubic shape (18 x 18 x 18 cm3). Besides measurements of fluence and dose rates in air or in phantom performed with thermoluminescence dosemeters (TLDs) and using the activation technique, dose and fluence profiles have been generated using a method based on gel dosemeters analysed with optical imaging. To check the consistency of the results, spectrometry measurements in the same irradiation volume have been performed by means of bubble detectors.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Planejamento da Radioterapia Assistida por Computador / Terapia por Captura de Nêutron de Boro / Análise de Falha de Equipamento / Nêutrons Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Risk_factors_studies Limite: Animals / Humans País/Região como assunto: Europa Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Planejamento da Radioterapia Assistida por Computador / Terapia por Captura de Nêutron de Boro / Análise de Falha de Equipamento / Nêutrons Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Risk_factors_studies Limite: Animals / Humans País/Região como assunto: Europa Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2004 Tipo de documento: Article