Your browser doesn't support javascript.
loading
Color stability of dry earth pigmented maxillofacial silicone A-2186 subjected to microwave energy exposure.
Kiat-amnuay, Sudarat; Johnston, Dennis A; Powers, John M; Jacob, Rhonda F.
Afiliação
  • Kiat-amnuay S; Department of Restorative Dentistry and Biomaterials, The University of Texas Dental Branch at Houston, Houston, TX 77030, USA. Sudarat.Kiat-amnuay@uth.tmc.edu
J Prosthodont ; 14(2): 91-6, 2005 Jun.
Article em En | MEDLINE | ID: mdl-16011619
ABSTRACT

PURPOSE:

The purpose of this study was to measure spectrophotometrically the color stability of pigmented A-2186 silicone maxillofacial elastomer with 10% by volume of titanium white dry earth opacifier before and after exposure to microwave energy over a simulated 1.5-year period of microwave sterilization. MATERIALS AND

METHODS:

A-2186 silicone elastomer opacified with titanium white dry earth pigment, pigmented with 5 cosmetic dry earth pigment colors [no pigment (control) group (Pc), red (Pr), yellow ochre (Py), burnt sienna (Po), and a mixture of Pr + Py + Po color group (P3)], was used in this study. Each of the 5 experimental groups consisted of 5 specimens. All specimens were placed in a 250 ml glass beaker filled with 150 ml of water (replenished for each microwave exposure). An exposure of 6 minutes was used 18 times (simulating 1.5 years of microwave sterilization with one 6 minute exposure monthly). Reflectance values were measured by spectrophotometer. Three- and two-way analyses of variance with repeated measures were performed for the color difference (DeltaE*) with the factors of group/color/months, and group/months, respectively. Means were compared by Tukey Honest Significant Difference (HSD) multiple range test calculated at the 0.05 level of significance using SPSS.

RESULTS:

The trained human eye can detect color changes (DeltaE*) greater than 1.0. Most DeltaE* values of the red pigment group at all intervals and the mixed pigment group at 15- and 18- month intervals increased significantly greater than 1.0 (p < 0.001) compared with the control group. Yellow and burnt sienna groups remained the most color stable over time with DeltaE* values below 0.35.

CONCLUSIONS:

Lack of color stability of red dry earth pigmented A-2186 silicone maxillofacial elastomers was clinically significant after 12-month exposure to microwave energy as compared with yellow, burnt sienna, and opacified A-2186 dry earth pigments.
Assuntos
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Elastômeros de Silicone / Pigmentação em Prótese / Dimetilpolisiloxanos / Prótese Maxilofacial / Micro-Ondas Limite: Humans Idioma: En Revista: J Prosthodont Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Elastômeros de Silicone / Pigmentação em Prótese / Dimetilpolisiloxanos / Prótese Maxilofacial / Micro-Ondas Limite: Humans Idioma: En Revista: J Prosthodont Ano de publicação: 2005 Tipo de documento: Article