[Individualized dose requirement for spiral-CT analysis of the abdomen]. / Individueller Dosisbedarf bei Spiral-CT-Untersuchungen des Abdomens.
Tschammler, A; Kenn, W; Dinkel, H P; Sandstede, J; Keberle, M; Tschammler, S.
Afiliação
  • Tschammler A; Institut für Röntgendiagnostik der Universität Würzburg. tschammler@roentgen.uni-wuerzburg.de
Rofo ; 177(8): 1123-30, 2005 Aug.
Article em De | MEDLINE | ID: mdl-16021545
PURPOSE: To search for individualized scan protocols that provide adequate diagnostic information with minimal radiation exposure for abdominal CT in adults. MATERIAL AND METHODS: Beginning with standard settings (120 kVp, 200 mA, 0.75 s, CTDI (w = 11.7 mGy)), which are in the lowest quartile of the actual German radiation dose survey, 119 adults were examined using a single-row detector helical CT with 8 mm collimation and a pitch of 1.5. The individualized scan protocol was defined by repeating the reference scan up to 3 times with different radiation doses following a predefined iteration scheme. The image qualities with standard dose and with individualized dose were assessed independently by 3 radiologists blinded to the exposure parameters. The individualized dose was correlated with the diameter of the patients. RESULTS: The patient diameters varied from 16 to 35 cm and correlated with individualized radiation doses CTDI (w) from 6.4 to 17.6 mGy. We found an exponential correlation (y = 52.3 x e (0.05 x); r(2) = 0.48; p < 0.001) between required tube current (mA) and a. p. diameter (cm) in the epigastric region in adults. CONCLUSION: Maintaining constant exposure parameters results in unnecessary radiation exposure in patients with a diameter of less than 27 cm measured in anterior-posterior direction in the epigastric area. The radiation exposure in adult abdominal CT can be reduced up to 45 % by individualized selection of the tube current without adversely affecting diagnostic performance.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Doses de Radiação / Proteção Radiológica / Radiometria / Radiografia Abdominal / Intensificação de Imagem Radiográfica / Tomografia Computadorizada Espiral Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline Limite: Adult / Female / Humans / Male Idioma: De Revista: Rofo Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Doses de Radiação / Proteção Radiológica / Radiometria / Radiografia Abdominal / Intensificação de Imagem Radiográfica / Tomografia Computadorizada Espiral Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline Limite: Adult / Female / Humans / Male Idioma: De Revista: Rofo Ano de publicação: 2005 Tipo de documento: Article