Your browser doesn't support javascript.
loading
Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.
Kraft, Clayton N; Burian, Björn; Diedrich, Oliver; Gessmann, Jan; Wimmer, Markus A; Pennekamp, Peter H.
Afiliação
  • Kraft CN; Department of Orthopedic Surgery, University of Bonn, D-53105 Bonn, Germany. umcb01@uni-bonn.de
J Biomed Mater Res A ; 75(1): 31-40, 2005 Oct 01.
Article em En | MEDLINE | ID: mdl-16078208
ABSTRACT
The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. Due to excellent physical and corrosion characteristics, CoCrMo-, Ti-6Al-4V-, and Ti-6Al-7Nb-alloys are commonly used in orthopedic surgery. Yet concern has been raised with regard to the implications of inevitable corrosion product of these metals on the surrounding biologic environment, particularly in the case of CoCrMo. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to these alloys, thereby drawing conclusions on their inflammatory potential. In 28 hamsters, utilizing the dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that the implant material CoCrMo has a marked impact on local microvascular parameters. While the Ti-alloys Ti-6Al-4V and Ti-6Al-7Nb induced only a transient and moderate inflammatory response, the implantation of a CoCrMo sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity and marked leukocyte extravasation. Animals with Ti-alloys showed a clear tendency of recuperation, while in all but one CoCrMo-treated animals, a breakdown of microcirculation prior to the scheduled end of the experiment was observed. Overall, the alloy Ti-6Al-7Nb was tolerated slightly better than Ti-6Al-4V under the chosen test conditions, though this discrepancy was not statistically significant. Conclusively, the commonly used biomaterials Ti-6Al-7Nb and Ti-6Al-4V induce a considerably lower inflammatory response in the skeletal muscle microvascular system, compared to a CoCrMo-alloy. With a minimum of adverse host reaction, our results indicate that for this particular model Ti-alloys are better tolerated than CoCrMo implant materials.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia / Titânio / Vitálio / Músculo Esquelético / Ligas / Microcirculação Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Biomed Mater Res A Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia / Titânio / Vitálio / Músculo Esquelético / Ligas / Microcirculação Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: J Biomed Mater Res A Ano de publicação: 2005 Tipo de documento: Article