Your browser doesn't support javascript.
loading
Effect of feed length on settleability, substrate uptake and storage in a sequencing batch reactor treating an industrial wastewater.
Dionisi, D; Majone, M; Levantesi, C; Bellani, A; Fuoco, A.
Afiliação
  • Dionisi D; Department of Chemistry, University of Rome "La Sapienza", p.le A. Moro 5, 00185 Rome, Italy.
Environ Technol ; 27(8): 901-8, 2006 Aug.
Article em En | MEDLINE | ID: mdl-16972386
ABSTRACT
The paper compares the performance of two Sequencing Batch Reactors (SBRs) treating the same industrial wastewater (composed of formic acid, ethylene glycol and methanol) operated at two different lengths of the feed. The two SBRs were operated in parallel under the same conditions of organic load (0.85 gCOD l(-1) d(-1)) and sludge age (about 10 d), the only difference being the length of the feed less than 1 min vs. 5 h. In this way the conditions of a plug flow reactor and of a completely mixed reactor were simulated. The two systems were compared on sludge settleability (related to filaments abundance and floc morphology), substrate uptake rates and polyhydroxyalkanoates (PHAs) storage rates. The main difference between the two systems was in the settling properties of the sludge both SVI and effluent solids were higher in the system with slow feed. With regard to filamentous microorganisms, even though both reactors were inoculated with the same sludge with high concentration of filaments, they were rapidly washed out from both systems. Microscopic observations showed that the reason for the different settling properties of the two sludges was in the floc structure, which was more compact in the system operated with fast feed. These data support the theory of the role of diffusion inside the flocs in determining the settling properties of the sludge. The maximum substrate uptake rates and PHA storage rates were similar in the two systems, showing that also the microorganisms grown at a constant and low substrate concentration were able to quickly increase their activity and to store PHAs when in the presence of a sudden change in substrate concentration.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Resíduos Industriais Idioma: En Revista: Environ Technol Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Resíduos Industriais Idioma: En Revista: Environ Technol Ano de publicação: 2006 Tipo de documento: Article