Your browser doesn't support javascript.
loading
Accurate, noninvasive measurement of total hemoglobin concentration with optoacoustic technique.
Brecht, H-P F; Prough, D S; Petrov, Y Y; Petrova, I Y; Deyo, D J; Esenaliev, R O.
Afiliação
  • Brecht HP; Center for Biomed. Eng., The University of Texas Medical Branch, Galveston, TX 77555, USA.
Article em En | MEDLINE | ID: mdl-17271689
ABSTRACT
The measurement of total hemoglobin concentration is currently invasive and time consuming. The optoacoustic technique may provide accurate and noninvasive measurements of total hemoglobin concentration by probing blood vessels. We studied the influence of blood vessel diameter and lateral displacement of the optoacoustic probe on accuracy of total hemoglobin concentration measurements with this technique.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Conf Proc IEEE Eng Med Biol Soc Ano de publicação: 2004 Tipo de documento: Article