Your browser doesn't support javascript.
loading
Accuracy of contacts calculated from 3D images of occlusal surfaces.
DeLong, R; Knorr, S; Anderson, G C; Hodges, J; Pintado, M R.
Afiliação
  • DeLong R; Minnesota Dental Research Center for Biomaterials and Biomechanics, Department of Restorative Sciences, University of Minnesota School of Dentistry, USA. delon002@umn.edu
J Dent ; 35(6): 528-34, 2007 Jun.
Article em En | MEDLINE | ID: mdl-17418474
ABSTRACT

OBJECTIVES:

Compare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.

METHODS:

Upper and lower full arch alginate impressions and vinyl polysiloxane centric interocclusal records were made of 12 subjects. Stone casts made from the alginate impressions and the interocclusal records were optically scanned. Three-dimensional virtual models of the dental arches and interocclusal records were constructed using the Virtual Dental Patient Software. Contacts calculated from the virtual interocclusal records and from the aligned upper and lower virtual arch models were compared to those identified clinically using 0.01mm shimstock and transillumination of the interocclusal record. Virtual contacts and transillumination contacts were compared by anatomical region and by contacting tooth pairs to shimstock contacts. Because there is no accepted standard for identifying occlusal contacts, methods were compared in pairs with one labeled "standard" and the second labeled "test". Accuracy was defined as the number of contacts and non-contacts of the "test" that were in agreement with the "standard" divided by the total number of contacts and non-contacts of the "standard".

RESULTS:

Accuracy of occlusal contacts calculated from virtual interocclusal records and aligned virtual casts compared to transillumination were 0.87+/-0.05 and 0.84+/-0.06 by region and 0.95+/-0.07 and 0.95+/-0.05 by tooth, respectively. Comparisons with shimstock were 0.85+/-0.15 (record), 0.84+/-0.14 (casts), and 81+/-17 (transillumination).

CONCLUSIONS:

The virtual record, aligned virtual arches, and transillumination methods of identifying contacts are equivalent, and show better agreement with each other than with the shimstock method.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Coroa do Dente / Imageamento Tridimensional / Oclusão Dentária Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Dent Ano de publicação: 2007 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Coroa do Dente / Imageamento Tridimensional / Oclusão Dentária Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Dent Ano de publicação: 2007 Tipo de documento: Article