[Rupture of the testicle: comparison of the echographic picture and operative findings]. / Fratture del testicolo: confronto fra quadri ecografici e reperti operatori.
Pecori, M; Repetti, F; Di Lascio, N; Santelli, G; Torcigliani, S; Tori, F; Paoli, R; Muraro, G B.
Afiliação
  • Pecori M; U.O. di Urologia e Radiologia 1. Ospedale di Lucca.
Arch Ital Urol Nefrol Androl ; 63 Suppl 2: 135-7, 1991 Jun.
Article em It | MEDLINE | ID: mdl-1836652
9 patients suffering from testicular rupture, owing to blunt scrotal trauma, were examined with ultrasound and then underwent surgical exploration. Sonography correctly diagnosed testicular rupture in 8 patients, 1 false-negative occurred. Clinical examination often is difficult in evaluating testicular trauma, sonography provides a useful tool for improved diagnosis in testicular rupture.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testículo / Ferimentos não Penetrantes / Contusões Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Humans / Male Idioma: It Revista: Arch Ital Urol Nefrol Androl Ano de publicação: 1991 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testículo / Ferimentos não Penetrantes / Contusões Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Humans / Male Idioma: It Revista: Arch Ital Urol Nefrol Androl Ano de publicação: 1991 Tipo de documento: Article