False-negative Histoplasma antigen in acute pulmonary histoplasmosis: the value of urinary concentration by ultrafiltration and heat denaturation of serum proteins in detection of Histoplasma antigen.
Pediatr Infect Dis J
; 28(5): 447-9, 2009 May.
Article
em En
| MEDLINE
| ID: mdl-19295461
We report an infant with localized pulmonary histoplasmosis in whom Histoplasma antibody assays, quantitative Histoplasma urine and serum antigen concentrations, and histopathologic findings of a mediastinal mass were nondiagnostic. A provisional diagnosis of histoplasmosis was established by using laboratory methods that increase the sensitivity of the antigen assay using ultrafiltration of urine and ethylenediaminetetraacetic acid/heat denaturation of serum proteins.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Desnaturação Proteica
/
Histoplasma
/
Histoplasmose
/
Pneumopatias Fúngicas
/
Antígenos de Fungos
Tipo de estudo:
Diagnostic_studies
Limite:
Humans
/
Infant
/
Male
Idioma:
En
Revista:
Pediatr Infect Dis J
Ano de publicação:
2009
Tipo de documento:
Article