Toward prompt gamma spectrometry for monitoring boron distributions during extra corporal treatment of liver metastases by boron neutron capture therapy: a Monte Carlo simulation study.
Appl Radiat Isot
; 67(7-8 Suppl): S359-61, 2009 Jul.
Article
em En
| MEDLINE
| ID: mdl-19394243
ABSTRACT
A Monte Carlo calculation was carried out for boron neutron capture therapy (BNCT) of extra corporal liver phantom. The present paper describes the basis for a subsequent clinical application of the prompt gamma spectroscopy set-up aimed at in vivo monitoring of boron distribution. MCNP code was used first to validate the homogeneity in thermal neutron field in the liver phantom and simulate the gamma ray detection system (collimator and detector) in the treatment room. The gamma ray of 478 keV emitted by boron in small specific region can be detected and a mathematical formalism was used for the tomography image reconstruction.