Aortoiliac intervention with distal protection to salvage a heterotopic renal transplant.
Ren Fail
; 31(7): 593-6, 2009.
Article
em En
| MEDLINE
| ID: mdl-19839857
A case of substantial debris captured by an embolic protection device placed in a patient's transplanted renal artery during common iliac artery angioplasty and stent placement is presented. To the authors knowledge, no previous literature exists pertaining to renal artery protection in patients with a history of a heterotopic renal transplant undergoing aortoiliac endovascular interventions.