Your browser doesn't support javascript.
loading
Clinical evaluation of automated refraction in anterior chamber pseudophakia.
Sunder Raj, P; Villada, J R; Myint, K; Lewis, A E; Akingbehin, T.
Afiliação
  • Sunder Raj P; Department of Ophthalmology, District General Hospital, Southport.
Br J Ophthalmol ; 75(1): 42-4, 1991 Jan.
Article em En | MEDLINE | ID: mdl-1991086
ABSTRACT
Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 85 eyes of 85 patients with an anterior chamber intraocular lens implant and a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 80 (94%) of these eyes. The agreement between autorefraction and clinical refraction data was 89% for spherical equivalence less than 0.51 dioptres (D), 91% for sphere power less than 0.51 D, 82% for cylinder power less than 0.51 D, and 91% for cylinder axis less than 11 degrees. Autorefraction provides acceptably accurate postoperative refraction values in anterior chamber pseudophakia.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Lentes Intraoculares Limite: Humans Idioma: En Revista: Br J Ophthalmol Ano de publicação: 1991 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Lentes Intraoculares Limite: Humans Idioma: En Revista: Br J Ophthalmol Ano de publicação: 1991 Tipo de documento: Article