Your browser doesn't support javascript.
loading
Radiation exposure of patient and physician during implantation and upgrade of cardiac resynchronization devices.
Butter, Christian; Schau, Thomas; Meyhoefer, Juergen; Neumann, Klaus; Minden, Hans H; Engelhardt, Joerg.
Afiliação
  • Butter C; Heart Center Brandenburg, Department of Cardiology, Bernau/Berlin, Germany. c.butter@immanuel.de
Pacing Clin Electrophysiol ; 33(8): 1003-12, 2010 Aug.
Article em En | MEDLINE | ID: mdl-20456650
ABSTRACT

BACKGROUND:

Cardiac resynchronization therapy (CRT) is often associated with extended fluoroscopic exposure during placement of the devices. The objective of this study was to measure the radiation exposure sustained by different parts of the body of patients and operators during fluoroscopically guided cardiac resynchronization device implantation.

METHODS:

Dosimetry data were prospectively recorded in a series of 104 consecutive patients, who underwent resynchronization device implantation or upgrade in our cardiac catheterization laboratory. Five Chipstrate dosimeters were fixed to the patient's skin around the thorax (right and left paravertebral, right and left parasternal, and sternal positions), one dosimeter was attached to the forehead, and one to the pubis. The operator was equipped with one dosimeter on the forehead at eye level and a ring dosimeter was worn on the right hand.

RESULTS:

Based on the maximum radiation dose of 9.2 mSv measured at the operator's hand in a single implantation session, it might be recommended to conservatively limit the number of implantations to four per month (an annual limit value of 500 mSv). At a mean dose of 1.2 mSv, this number can be increased sevenfold.

CONCLUSION:

In patients, incipient deterministic radiation effects can theoretically be observed at dose area product >400 Gy*cm(2), a dose applied in 2.9% of CRT implantation procedures. Special follow-up programs are considered necessary for these patients and for operators, as the latter may be exposed over many years given the unknown long-term impact of chronic radiation exposure and the nature of current complex electrophysiology and device procedures.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Doses de Radiação / Radiografia Intervencionista / Exposição Ocupacional / Desfibriladores Implantáveis / Terapia de Ressincronização Cardíaca Limite: Aged / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Doses de Radiação / Radiografia Intervencionista / Exposição Ocupacional / Desfibriladores Implantáveis / Terapia de Ressincronização Cardíaca Limite: Aged / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2010 Tipo de documento: Article