Your browser doesn't support javascript.
loading
Bone regeneration in the presence of a synthetic hydroxyapatite/silica oxide-based and a xenogenic hydroxyapatite-based bone substitute material.
Kruse, A; Jung, R E; Nicholls, F; Zwahlen, R A; Hämmerle, C H F; Weber, F E.
Afiliação
  • Kruse A; Department of Cranio-Maxillofacial Surgery, Oral Biotechnology & Bioengineering, University Hospital Zurich, Switzerland.
Clin Oral Implants Res ; 22(5): 506-11, 2011 May.
Article em En | MEDLINE | ID: mdl-21121956
ABSTRACT

OBJECTIVES:

A comparison of synthetic hydroxyapatite/silica oxide, xenogenic hydroxyapatite-based bone substitute materials with empty control sites in terms of bone regeneration enhancement in a rabbit calvarial four non-critical-sized defect model.

METHODS:

In each of six rabbits, four bicortical calvarial bone defects were generated. The following four treatment modalities were randomly allocated (1) empty control site, (2) synthetic hydroxyapatite/silica oxide-based (HA/SiO) test granules, (3) xenogenic hydroxyapatite -based granules, (4) synthetic hydroxyapatite/silica oxide -based (HA/SiO) test two granules. The results of the latter granules have not been reported due to their size being three times bigger than the other two granule types. After 4 weeks, the animals were sacrificed and un-decalcified sections were obtained for histological analyses. For statistical analysis, the Kruskal-Wallis test was applied (P<0.05).

RESULTS:

Histomorphometric analysis showed an average area fraction of newly formed bone of 12.32±10.36% for the empty control, 17.47±6.42% for the xenogenic hydroxyapatite -based granules group, and 21.2±5.32% for the group treated with synthetic hydroxyapatite/silica oxide -based granules. Based on the middle section, newly formed bone bridged the defect to 38.33±37.55% in the empty control group, 54.33±22.12% in the xenogenic hydroxyapatite -based granules group, and to 79±13.31% in the synthetic hydroxyapatite/silica oxide -based granules group. The bone-to-bone substitute contact was 46.38±18.98% for the xenogenic and 59.86±14.92% for the synthetic hydroxyapatite/silica oxide-based granules group. No significant difference in terms of bone formation and defect bridging could be detected between the two bone substitute materials or the empty defect.

CONCLUSION:

There is evidence that the synthetic hydroxyapatite/silica oxide granules provide comparable results with a standard xenogenic bovine mineral in terms of bone formation and defect bridging in non-critical size defects.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Matriz Óssea / Regeneração Óssea / Durapatita / Dióxido de Silício / Substitutos Ósseos / Minerais Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Clin Oral Implants Res Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Matriz Óssea / Regeneração Óssea / Durapatita / Dióxido de Silício / Substitutos Ósseos / Minerais Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Clin Oral Implants Res Ano de publicação: 2011 Tipo de documento: Article