Your browser doesn't support javascript.
loading
Array-based MLPA to detect recurrent copy number variations in patients with idiopathic mental retardation.
Rooms, Liesbeth; Vandeweyer, Geert; Reyniers, Edwin; van Mol, Kurt; de Canck, Ilse; Van der Aa, Nathalie; Rossau, Rudi; Kooy, R Frank.
Afiliação
  • Rooms L; Department of Medical Genetics, University of Antwerp and University Hospital, Antwerp, Belgium.
Am J Med Genet A ; 155A(2): 343-8, 2011 Feb.
Article em En | MEDLINE | ID: mdl-21271651
ABSTRACT
Microdeletions, either subtelomeric or interstitial, are responsible for the mental handicap in approximately 10-20% of all patients. Currently, Multiplex Ligation-dependent Probe Amplification (MLPA) is widely used to detect these small aberrations in a routine fashion. Although cost-effective, the throughput is low and the degree of multiplexing is limited to maximally 40-50 probes. Therefore, we developed an array-based MLPA method, with probes identified by unique tag sequences, allowing the simultaneous analysis of 180 probes in a single experiment thereby covering all known mental retardation loci with at least two probes. We screened 120 patients with idiopathic mental retardation. In this group we detected 6 aberrations giving a detection rate of 5%, consistent with similar studies. In addition we tested 293 patients with mental retardation who were negative for fragile X syndrome and commercially available subtelomeric MLPA. We found seven causative rearrangements in this group (detection rate of 2.4%) thereby illustrating the value of including probes for interstitial microdeletion syndromes and additional probes in the telomeric regions in targeted screening sets for mental retardation. Array-based MLPA may thus be a good candidate to develop probe sets that rapidly detect copy number changes of disease associated loci in the human genome. This method may become a valuable tool in a routine diagnostic setting as it is a fast, user-friendly and relatively low-cost technique providing straightforward results requiring only 125 ng of genomic DNA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Deleção Cromossômica / Análise em Microsséries / Deficiência Intelectual Limite: Humans Idioma: En Revista: Am J Med Genet A Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Deleção Cromossômica / Análise em Microsséries / Deficiência Intelectual Limite: Humans Idioma: En Revista: Am J Med Genet A Ano de publicação: 2011 Tipo de documento: Article