Your browser doesn't support javascript.
loading
Dosimetric feasibility study for an extracorporeal BNCT application on liver metastases at the TRIGA Mainz.
Blaickner, M; Kratz, J V; Minouchehr, S; Otto, G; Schmidberger, H; Schütz, C; Vogtländer, L; Wortmann, B; Hampel, G.
Afiliação
  • Blaickner M; Health & Environment Department-Molecular Medicine, AIT Austrian Institute of Technology GmbH, Muthgasse 11, A-1190 Vienna, Austria. matthias.blaickner@ait.ac.at
Appl Radiat Isot ; 70(1): 139-43, 2012 Jan.
Article em En | MEDLINE | ID: mdl-21872481
ABSTRACT
This study investigates the dosimetric feasibility of Boron Neutron Capture Therapy (BNCT) of explanted livers in the thermal column of the research reactor in Mainz. The Monte Carlo code MCNP5 is used to calculate the biologically weighted dose for different ratios of the (10)B-concentration in tumour to normal liver tissue. The simulation results show that dosimetric goals are only partially met. To guarantee effective BNCT treatment the organ has to be better shielded from all gamma radiation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Terapia por Captura de Nêutron de Boro / Neoplasias Hepáticas / Modelos Biológicos Limite: Humans Idioma: En Revista: Appl Radiat Isot Ano de publicação: 2012 Tipo de documento: Article