Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty.
Mao, Xinzhan; Tay, Guan H; Godbolt, David B; Crawford, Ross W.
Afiliação
  • Mao X; Department of Orthopaedics, The Second Xiangya Hospital, Central-South University, Changsha, China.
J Arthroplasty ; 27(3): 493.e13-7, 2012 Mar.
Article em En | MEDLINE | ID: mdl-21955792
The incidence of pseudotumor formation has been reported to be 1% in patients with metal-on-metal resurfacing arthroplasties. This complication is not exclusive to these patients. We report a case of pseudotumor formation secondary to femoral head-neck corrosion after a metal-on-polyethylene uncemented total hip arthroplasty.