A comparison of NCO and NCA transfer methods for biological solid-state NMR spectroscopy.
J Magn Reson
; 214(1): 81-90, 2012 Jan.
Article
em En
| MEDLINE
| ID: mdl-22116035
Three different techniques (adiabatic passage Hartman-Hahn cross-polarization, optimal control designed pulses, and EXPORT) are compared for transferring (15)N magnetization to (13)C in solid-state NMR experiments under magic-angle-spinning conditions. We demonstrate that, in comparison to adiabatic passage Hartman-Hahn cross-polarization, optimal control transfer pulses achieve similar or better transfer efficiencies for uniformly-(13)C,(15)N labeled samples and are generally superior for samples with non-uniform labeling schemes (such as 1,3- and 2-(13)C glycerol labeling). In addition, the optimal control pulses typically use substantially lower average RF field strengths and are more robust with respect to experimental variation and RF inhomogeneity. Consequently, they are better suited for demanding samples.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Biopolímeros
/
Algoritmos
/
Espectroscopia de Ressonância Magnética
Tipo de estudo:
Diagnostic_studies
Idioma:
En
Revista:
J Magn Reson
Ano de publicação:
2012
Tipo de documento:
Article