X-ray induced DNA double-strand breaks in coronary CT angiography: comparison of sequential, low-pitch helical and high-pitch helical data acquisition.
Brand, Michael; Sommer, Matthias; Achenbach, Stephan; Anders, Katharina; Lell, Michael; Löbrich, Markus; Uder, Michael; Kuefner, Michael A.
Afiliação
  • Brand M; Department of Radiology, University of Erlangen-Nürnberg, Maximiliansplatz 1, D-91054 Erlangen, Germany. michael.brand@uk-erlangen.de
Eur J Radiol ; 81(3): e357-62, 2012 Mar.
Article em En | MEDLINE | ID: mdl-22178288
ABSTRACT

BACKGROUND:

Aim of this study was to compare DNA double-strand breaks (DSBs) in blood lymphocytes of patients undergoing high-pitch helical, low-pitch helical and sequential coronary CT angiography. METHODS AND

RESULTS:

66 patients were examined with various scan protocols and modes (low-pitch helical scan 100-120 kV, 320-438 mAs/rot, pitch 0.18-0.39, with or without ECG-pulsing, n=35; prospectively ECG-triggered high-pitch helical scan 100-120 kV, 320-456 mAs/rotation, pitch 3.2-3.4, n=19; prospectively ECG-triggered sequential scan 100-120 kV, 150-300 mAs or 320-370 mAs/rotation, n=12) either using a 64-slice or 128-slice dual-source CT or a 128-slice single source CT scanner. Blood samples were obtained before and 30 min after CT and DSBs were analyzed in isolated lymphocytes using γ-H2AX immunofluorescence microscopy. A significant increase of DSBs was measurable 30 min after CTA (range 0.01-0.71/cell). CT induced DSBs showed a significant correlation with the estimated effective dose (ρ=0.90, p<0.00001). Both prospectively ECG-triggered sequential (0.10 DSBs/cell, 176 mGy cm, p<0.00001) and high-pitch helical scan protocols (0.03 DSBs/cell, 109 mGy cm, p<0.00001) led to a significant reduction of median DLP and DSB levels compared to low-pitch helical scans (0.34 DSBs/cell, 828 mGy cm). A reduction of the tube voltage resulted in significantly lower whereas additional calcium scoring resulted in elevated DLP and DNA damages (p<0.05 each).

CONCLUSION:

In coronary CTA, data acquisition protocols have a significant influence on the X-ray induced DSB levels. Using γ-H2AX immunofluorescence microscopy different scan modes in different CT generations can be compared concerning their biological impact.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Linfócitos / Angiografia Coronária / Doença das Coronárias / Tomografia Computadorizada Espiral / Quebras de DNA de Cadeia Dupla / Técnicas de Imagem de Sincronização Cardíaca Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Linfócitos / Angiografia Coronária / Doença das Coronárias / Tomografia Computadorizada Espiral / Quebras de DNA de Cadeia Dupla / Técnicas de Imagem de Sincronização Cardíaca Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2012 Tipo de documento: Article