Volume-targeted ventilation in infants born at or near term.
Chowdhury, Olie; Rafferty, Gerrard F; Lee, Silke; Hannam, Simon; Milner, Anthony D; Greenough, Anne.
Afiliação
  • Chowdhury O; Division of Asthma, Allergy & Lung Biology, MRC-Asthma UK Centre in Allergic Mechanisms of Asthma, King's College London, UK.
Arch Dis Child Fetal Neonatal Ed ; 97(4): F264-6, 2012 Jul.
Article em En | MEDLINE | ID: mdl-22194469
ABSTRACT

OBJECTIVES:

To determine the impact of different volume-targeted (VT) levels during volume-targeted ventilation (VTV) on the work of breathing (WOB) of infants born at or near term and to investigate whether a level of VT reduced the WOB below that experienced on respiratory support without VT.

DESIGN:

Prospective crossover study. PATIENTS Sixteen infants, median gestational age of 38 (range 34-41) weeks, birth weight of 3.1 (range 1.5-4.1) kg and postnatal age of 5 (range 2-17) days were studied. The infants were receiving time-cycled, pressure-limited ventilation in a continuous mandatory or in a triggered mode.

INTERVENTIONS:

The infants were studied first without VT (baseline) and then at VT levels of 4, 5 and 6 ml/kg delivered in a random order. After each VT level, the infants were returned to baseline. MAIN OUTCOME

MEASURE:

The WOB was assessed by measuring the transdiaphragmatic pressure-time product (PTPdi).

RESULTS:

One infant became apnoeic at VT of 6 ml/kg. At a VT level of 4 ml/kg, four infants were making such vigorous respiratory efforts that no inflations were delivered. The median PTPdi was higher at a VT level of 4 ml/kg than at 5 ml/kg (p<0.01) or 6 ml/kg (p<0.001). Only at a VT level of 6 ml/kg was the median PTPdi lower than that at baseline (p<0.01).

CONCLUSION:

Low VT levels (4 ml/kg) during VTV increase the WOB in ventilated infants born at term or near term. The results suggest that a VT level of 6 ml/kg could be used to reduce the WOB.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Cuidado do Lactente / Doenças do Recém-Nascido Tipo de estudo: Clinical_trials / Evaluation_studies / Observational_studies Limite: Humans / Newborn Idioma: En Revista: Arch Dis Child Fetal Neonatal Ed Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Cuidado do Lactente / Doenças do Recém-Nascido Tipo de estudo: Clinical_trials / Evaluation_studies / Observational_studies Limite: Humans / Newborn Idioma: En Revista: Arch Dis Child Fetal Neonatal Ed Ano de publicação: 2012 Tipo de documento: Article