Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis.
Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R; Block, Alec M; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas.
Afiliação
  • Castillo R; Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Phys Med Biol ; 57(7): 1855-71, 2012 Apr 07.
Article em En | MEDLINE | ID: mdl-22411124
ABSTRACT
To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R² = 0.99). Respective values for the average DSC, NDSC(1 mm) and NDSC(2 mm) for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Circulação Pulmonar / Carcinoma Pulmonar de Células não Pequenas / Ventilação Pulmonar / Tomografia Computadorizada Quadridimensional / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Circulação Pulmonar / Carcinoma Pulmonar de Células não Pequenas / Ventilação Pulmonar / Tomografia Computadorizada Quadridimensional / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2012 Tipo de documento: Article