Your browser doesn't support javascript.
loading
Determination of lipid raft partitioning of fluorescently-tagged probes in living cells by Fluorescence Correlation Spectroscopy (FCS).
Marquer, Catherine; Lévêque-Fort, Sandrine; Potier, Marie-Claude.
Afiliação
  • Marquer C; Centre de Recherche de l'Institut du Cerveau et de la Moelle Épinière, Hôpital de la Pitié-Salpêtrière. catherine.marquer@upmc.fr
J Vis Exp ; (62): e3513, 2012 Apr 06.
Article em En | MEDLINE | ID: mdl-22508446
ABSTRACT
In the past fifteen years the notion that cell membranes are not homogenous and rely on microdomains to exert their functions has become widely accepted. Lipid rafts are membrane microdomains enriched in cholesterol and sphingolipids. They play a role in cellular physiological processes such as signalling, and trafficking but are also thought to be key players in several diseases including viral or bacterial infections and neurodegenerative diseases. Yet their existence is still a matter of controversy. Indeed, lipid raft size has been estimated to be around 20 nm, far under the resolution limit of conventional microscopy (around 200 nm), thus precluding their direct imaging. Up to now, the main techniques used to assess the partition of proteins of interest inside lipid rafts were Detergent Resistant Membranes (DRMs) isolation and co-patching with antibodies. Though widely used because of their rather easy implementation, these techniques were prone to artefacts and thus criticized. Technical improvements were therefore necessary to overcome these artefacts and to be able to probe lipid rafts partition in living cells. Here we present a method for the sensitive analysis of lipid rafts partition of fluorescently-tagged proteins or lipids in the plasma membrane of living cells. This method, termed Fluorescence Correlation Spectroscopy (FCS), relies on the disparity in diffusion times of fluorescent probes located inside or outside of lipid rafts. In fact, as evidenced in both artificial membranes and cell cultures, probes would diffuse much faster outside than inside dense lipid rafts. To determine diffusion times, minute fluorescence fluctuations are measured as a function of time in a focal volume (approximately 1 femtoliter), located at the plasma membrane of cells with a confocal microscope (Fig. 1). The auto-correlation curves can then be drawn from these fluctuations and fitted with appropriate mathematical diffusion models. FCS can be used to determine the lipid raft partitioning of various probes, as long as they are fluorescently tagged. Fluorescent tagging can be achieved by expression of fluorescent fusion proteins or by binding of fluorescent ligands. Moreover, FCS can be used not only in artificial membranes and cell lines but also in primary cultures, as described recently. It can also be used to follow the dynamics of lipid raft partitioning after drug addition or membrane lipid composition change.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Microdomínios da Membrana / Corantes Fluorescentes Limite: Humans Idioma: En Revista: J Vis Exp Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Microdomínios da Membrana / Corantes Fluorescentes Limite: Humans Idioma: En Revista: J Vis Exp Ano de publicação: 2012 Tipo de documento: Article