Your browser doesn't support javascript.
loading
Achieving high quality colonoscopy: using graphical representation to measure performance and reset standards.
Rajasekhar, P T; Rutter, M D; Bramble, M G; Wilson, D W; East, J E; Greenaway, J R; Saunders, B P; Lee, T J W; Barton, R; Hungin, A P S; Rees, C J.
Afiliação
  • Rajasekhar PT; South Tyneside Foundation Hospital, South Shields, UK.
Colorectal Dis ; 14(12): 1538-45, 2012 Dec.
Article em En | MEDLINE | ID: mdl-22540766
AIM: Completeness and thoroughness of colonoscopy are measured by the caecal intubation rate (CIR) and the adenoma detection rate (ADR). National standards are ≥ 90% and ≥ 10% respectively. Variability in CIR and ADR have been demonstrated but comparison between individuals and units is difficult. We aimed to assess the performance of colonoscopy in endoscopy units in the northeast of England. METHOD: Data on colonoscopy performance and sedation use were collected over 3 months from 12 units. Colonoscopies performed by screening colonoscopists were included for the CIR only. Funnel plots with upper and lower 95% confidence limits for CIR and ADR were created. RESULTS: CIR was 92.5% (n = 5720) and ADR 15.9% (n = 4748). All units and 128 (99.2%) colonoscopists were above the lower limit for CIR. All units achieved the ADR standard with 10 above the upper limit. Ninety-nine (76.7%) colonoscopists were above 10%, 16 (12.4%) above the upper limit and 7 (5.4%) below the lower limit. Median medication doses were 2.2 mg midazolam, 29.4 mg pethidine and 83.3 µg fentanyl. In all, 15.1% of colonoscopies were unsedated. Complications were bleeding (0.10%) and perforation (0.02%). There was one death possibly related to bowel preparation. CONCLUSION: Results indicate that colonoscopies are performed safely and to a high standard. Funnel plots can highlight variability and areas for improvement. Analyses of ADR presented graphically around the global mean suggest that the national standard should be reset at 15%.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Cateterismo / Adenoma / Colonoscopia / Neoplasias do Colo / Sedação Profunda Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Colorectal Dis Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Cateterismo / Adenoma / Colonoscopia / Neoplasias do Colo / Sedação Profunda Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Colorectal Dis Ano de publicação: 2012 Tipo de documento: Article