Novel compact dual-band LOROP camera with telecentricity.
Park, Kwang-Woo; Han, Jeong-Yeol; Bae, Jongin; Kim, Sug-Whan; Kim, Chang-Woo; Rhee, Hyug-Gyo; Yang, Ho-Soon; Lee, Yun-Woo.
Afiliação
  • Park KW; Agency for Defense Development, Daejeon 305-152, Korea.
Opt Express ; 20(10): 10921-32, 2012 May 07.
Article em En | MEDLINE | ID: mdl-22565716
We report a new dual band compact oblique photography camera (LC11) that is the first to benefit from the incorporation of telecentricity. LC11 has a common front end F/6.6 telescope with 280 mm in aperture that forms its electro-optical (EO, F/7.5) and MWIR (F/5.6) modules. The design allows a substantial reduction in volume and weight due to i) the EO/MWIR compensator and relay lens groups arranged very close to the primary mirror (M1), and ii) light-weighted M1 and SiC main frame (MF) structure. Telecentricity of up to 2 and 0.2 degrees for the EO and MWIR modules, respectively, is achieved by balancing optical power among all lenses. The initial field test shows 0.32 ± 0.05 (EO)/0.20 ± 0.06 (MWIR) in measured MTF at 28 (EO) and 13 (MWIR) cycles/mm in target frequency, and an improved operability with a greater reduction in operational volume and mass than other existing LOROP cameras.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Opt Express Ano de publicação: 2012 Tipo de documento: Article