Your browser doesn't support javascript.
loading
Nanophthalmos: quantitative analysis of anterior chamber angle configuration before and after cataract surgery.
Seki, Masaaki; Fukuchi, Takeo; Ueda, Jun; Suda, Kieko; Nakatsue, Tomoko; Tanaka, Yoko; Togano, Tetsuya; Yamamoto, Susumu; Hara, Hiroaki; Abe, Haruki.
Afiliação
  • Seki M; Department of Ophthalmology, Division of Ophthalmology and Visual Science, Graduated School of Medical and Dental Sciences, Niigata University, Niigata, Japan. masaaki.seki@gmail.com
Br J Ophthalmol ; 96(8): 1108-16, 2012 Aug.
Article em En | MEDLINE | ID: mdl-22661652
ABSTRACT
BACKGROUND/

AIMS:

To analyse quantitatively the anterior segment configuration in eyes with nanophthalmos before and after cataract surgery.

METHODS:

This was a retrospective, non-comparative, interventional case series. Eleven eyes in eight patients with nanophthalmos who underwent phacoemulsification and intraocular lens implantation were identified from the department's surgical log, and their clinical records were retrospectively reviewed. Main outcome measures were as follows visual acuity, intraocular pressure (IOP), axial length and the following ultrasound biomicroscopy parameters angle opening distance at 500 µm anterior to the scleral spur (AOD500), trabecular-iris angle (TIA) and trabecular ciliary process distance.

RESULTS:

The mean axial length of the eyes was 17.3 ± 1.7 mm. AOD500 and TIA increased after cataract surgery (p<0.005). Smaller axial length, AOD500 and TIA before cataract surgery were observed in eyes with preoperative IOP elevation than those without preoperative IOP elevation (p<0.05). Lower postoperative IOP was correlated with greater AOD500 and TIA before cataract surgery (p<0.05).

CONCLUSIONS:

Cataract surgery deepened the anterior chamber and widened the anterior chamber angle in nanophthalmic eyes. Cataract surgery may have beneficial effects on IOP in eyes with nanophthalmos.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iris / Microftalmia / Corpo Ciliar / Facoemulsificação / Implante de Lente Intraocular / Câmara Anterior Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Ophthalmol Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iris / Microftalmia / Corpo Ciliar / Facoemulsificação / Implante de Lente Intraocular / Câmara Anterior Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Ophthalmol Ano de publicação: 2012 Tipo de documento: Article