Reappraisal of spontaneous closure rate of idiopathic full-thickness macular holes.
Open Ophthalmol J
; 6: 73-4, 2012.
Article
em En
| MEDLINE
| ID: mdl-22934124
ABSTRACT
We retrospectively reviewed the records of 142 eyes of 138 patients with idiopathic full-thickness macular hole. Spontaneous closure of idiopathic full-thickness macular hole was observed in five eyes (3.5%) of four patients before the planned vitrectomy. In the era when surgical treatment was not available for macular hole, the rate of spontaneous closure of idiopathic full-thickness macular hole was reported as 6.2%. Among several case reports on spontaneous closure of idiopathic full-thickness macular hole based on the optical coherence tomography images only one study reported the rate of spontaneous closure as 2.7%. According to the previous reports and our results, small idiopathic full-thickness macular holes may close spontaneously in a few percent of all macular hole cases. The rate of spontaneous closure may be affected by the waiting time before vitrectomy.