A niobium water target for routine production of [¹8F]Fluoride with a MC 17 cyclotron.
Siikanen, J; Ohlsson, T; Medema, J; Van-Essen, J; Sandell, A.
Afiliação
  • Siikanen J; Medical Radiation Physics, Lund University Hospital, Barngatan 2:1, 221 85 Lund, Sweden. jonathan.siikanen@med.lu.se
Appl Radiat Isot ; 72: 133-6, 2013 Feb.
Article em En | MEDLINE | ID: mdl-23208244
ABSTRACT
A [(18)F]Fluoride water target was constructed for a Scanditronix MC 17 cyclotron, without a beam line, with a typical wide beam of ∼30 × 5 mm(2). Niobium was used as target chamber material. One hour irradiation with 45µA protons yields about 110 GBq [(18)F]Fluoride. The saturation yield is 8.0 ± 0.6 GBq/µA (EOB). The FDG yield is 60 ± 5% (EOS) with a TracerLab MX (G.E. Healthcare). More than 100 GBq FDG is routinely produced after a 2h irradiation.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Appl Radiat Isot Ano de publicação: 2013 Tipo de documento: Article