Your browser doesn't support javascript.
loading
Compressed sensing reconstruction improves sensitivity of variable density spiral fMRI.
Holland, D J; Liu, C; Song, X; Mazerolle, E L; Stevens, M T; Sederman, A J; Gladden, L F; D'Arcy, R C N; Bowen, C V; Beyea, S D.
Afiliação
  • Holland DJ; Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK.
Magn Reson Med ; 70(6): 1634-43, 2013 Dec.
Article em En | MEDLINE | ID: mdl-23390043
ABSTRACT

PURPOSE:

Functional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction of variable density spiral fMRI.

METHODS:

Three different CS-reconstructed 1-shot variable density spirals were explored (corresponding to 28%, 35%, and 46% under-sampling), and compared with conventional 1-shot and 2-shot Archimedean spirals acquired using matched echo time and volume repetition time. fMRI maps were reconstructed with or without CS MRI and sensitivity was compared using identically matched voxels.

RESULTS:

The results demonstrated that an l1 -norm based CS reconstruction only led to an increase in functional contrast when applied to 28% under-sampled data. A whole brain t-contrast map revealed that 2-shot uniformly sampled spiral and 28% under-sampled spiral data reconstructed with CS yield equivalent sensitivity, even with matched echo time and volume repetition time

CONCLUSION:

VD spiral exhibits a useful operating range, in the region of 25-30% under-sampling, for which CS reconstruction can be used to increase the sensitivity of fMRI to brain activity. Using CS, VD acquisitions achieve the same sensitivity as 2-shot Archimedean acquisitions, but require only a single shot.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mapeamento Encefálico / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Córtex Cerebral / Compressão de Dados / Potenciais Evocados Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Magn Reson Med Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mapeamento Encefálico / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Córtex Cerebral / Compressão de Dados / Potenciais Evocados Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Magn Reson Med Ano de publicação: 2013 Tipo de documento: Article