Your browser doesn't support javascript.
loading
Monte Carlo simulation of NaI(TL) detector in a shadow-shield scanning bed whole-body monitor for uniform and axial cavity activity distribution in a BOMAB phantom.
Akar, D K; Patni, H K; Nadar, M Y; Ghare, V P; Rao, D D.
Afiliação
  • Akar DK; Internal Dosimetry Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India. akardeep@barc.gov.in
Radiat Prot Dosimetry ; 155(3): 292-9, 2013 Jul.
Article em En | MEDLINE | ID: mdl-23390143
ABSTRACT
This study presents the simulation results for 10.16 cm diameter and 7.62 cm thickness NaI(Tl) detector response, which is housed in a partially shielded scanning bed whole-body monitor (WBM), due to activity distributed in the axial cavities provided in the Indian reference BOMAB phantom. Experimental detection efficiency (DE) for axial cavity activity distribution (ACAD) in this phantom for photon emissions of (133)Ba, (137)Cs and (60)Co is used to validate DEs estimated using Monte Carlo code FLUKA. Simulations are also carried out to estimate DEs due to uniform activity distribution (UAD) as in the standard BOMAB phantom. The results show that the DE is ∼3.8 % higher for UAD when compared with ACAD in the case of (40)K (1460 keV) and this relative difference increases to ∼7.0 % for (133)Ba (∼356 keV) photons. The corresponding correction factors for calibration with Indian phantom are provided. DEs are also simulated for activity distributed as a planar disc at the centre of the axial cavity in each part of the BOMAB phantom (PDAD) and the deviations of these DEs are within 1 % of the ACAD results. Thus, PDAD can also be used for ACAD in scanning geometry. An analytical solution for transmitted mono-energetic photons from a two-dimensional slab is provided for qualitative explanation of difference in DEs due to variation in activity distributions in the phantom. The effect on DEs due to different phantom part dimensions is also studied and lower DEs are observed for larger parts.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Sódio / Tálio / Monitoramento de Radiação / Método de Monte Carlo / Contagem Corporal Total / Imagens de Fantasmas / Imagem Corporal Total / Iodetos Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Sódio / Tálio / Monitoramento de Radiação / Método de Monte Carlo / Contagem Corporal Total / Imagens de Fantasmas / Imagem Corporal Total / Iodetos Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2013 Tipo de documento: Article