Your browser doesn't support javascript.
loading
Determination of warfarin alcohols by ultra-high performance liquid chromatography-tandem mass spectrometry: application to in vitro enzyme kinetic studies.
Alshogran, Osama Y; Ocque, Andrew J; Zhao, Jielu; Day, Billy W; Leblond, François A; Pichette, Vincent; Nolin, Thomas D.
Afiliação
  • Alshogran OY; Center for Clinical Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States; Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States.
  • Ocque AJ; Center for Clinical Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States; Department of Pharmacy and Therapeutics, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States.
  • Zhao J; Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States.
  • Day BW; Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States.
  • Leblond FA; Service de Néphrologie et Centre de Recherche, Hôpital Maisonneuve-Rosemont, Montréal, Québec, Canada.
  • Pichette V; Service de Néphrologie et Centre de Recherche, Hôpital Maisonneuve-Rosemont, Montréal, Québec, Canada; Département de Pharmacologie, Université de Montréal, Montréal, Québec, Canada.
  • Nolin TD; Center for Clinical Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States; Department of Pharmacy and Therapeutics, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, United States. Electronic address: nolin@pitt.edu.
Article em En | MEDLINE | ID: mdl-24291722
ABSTRACT
A sensitive, accurate, and reproducible ultra-high performance liquid chromatography-tandem mass spectrometry method was developed and validated for determination of warfarin and its alcohol metabolites (RS/SR- and RR/SS-warfarin alcohol) in 10mM Tris-HCl incubation buffer (pH 7.4). Sample preparation involved acidification with 4% formic acid, followed by liquid-liquid extraction using methyl tert-butyl ether. Chromatographic separation was achieved using a Hypersil Gold C18 (2.1mm×100mm, 1.9µm) analytical column with gradient elution of solvent A (water containing 0.01% formic acid) and solvent B (acetonitrile containing 0.1% formic acid). The flow rate was 0.4mL/min and the total run time was 5min. Detection of analytes was performed using heated electrospray ionization (negative mode) and selected reaction monitoring. Excellent linearity was observed for all analytes over the standard curve concentration ranges of 100-10,000ng/mL for warfarin, and 0.5-250ng/mL for warfarin alcohols. The intra- and inter-day accuracy and precision for analytes were within ±10.0%. Excellent recovery and negligible matrix effects were observed. The method is robust, sensitive, accurate and reproducible, and was successfully applied to in vitro enzyme kinetic studies of warfarin.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Varfarina / Cromatografia Líquida / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Varfarina / Cromatografia Líquida / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2014 Tipo de documento: Article