Your browser doesn't support javascript.
loading
Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures.
Galvão, Mariana Bulhoes; Camporesi, Matteo; Tortamano, André; Dominguez, Gladys Cristina; Defraia, Efisio.
Afiliação
  • Galvão MB; Department of Orthodontic, University of Florence, Via Ponte di Mezzo 46/48, Florence, 50100, Italy. matteo_camporesi@yahoo.it.
Prog Orthod ; 14: 9, 2013 May 23.
Article em En | MEDLINE | ID: mdl-24325886
ABSTRACT

BACKGROUND:

The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch.

METHODS:

All tests (a total of 480 tests) were carried out in a dry state on a universal testing machine with a testing model consisting of three 0.022-in. monocrystalline ceramic preadjusted brackets (from the maxillary right second premolar through the right central incisor). The canine bracket was bonded to a sliding bar that allowed for different vertical positions. The frictional forces generated by a 0.012- and 0.014-in. superelastic nickel titanium wire (SENT) with conventional and nonconventional ligatures at various amounts of canine misalignment (1.5, 3.0, 4.5, and 6.0 mm) were recorded. Comparisons between the different types of bracket-wire-ligature systems were carried out by means of analysis of variance on ranks with Tukey's post hoc test (P<0.05).

RESULTS:

No significant differences were assessed among the three types of monocrystalline brackets with NCEL when coupled with 0.012-in. SENT. Radiance brackets with NCEL coupled with 0.014-in. SENT showed significantly greater frictional force than Inspire Ice brackets and Pure brackets with NCEL. A significantly greater amount of frictional force was generated with CEL when compared with NCEL for all the tested variables, with the exception of the Pure brackets with 0.012-in. SENT at 1.5 and 3.0 mm of canine misalignment where similar frictional forces were found.

CONCLUSIONS:

Nonconventional elastomeric ligatures are able to reduce friction in monocrystalline ceramic brackets.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cerâmica / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico / Elastômeros Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Prog Orthod Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cerâmica / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico / Elastômeros Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Prog Orthod Ano de publicação: 2013 Tipo de documento: Article