Pharmacologically induced erect penile length and stretched penile length are both good predictors of post-inflatable prosthesis penile length.
Int J Impot Res
; 26(4): 128-31, 2014.
Article
em En
| MEDLINE
| ID: mdl-24430278
Inflatable penile prosthesis (IPP) remains the gold standard for the surgical treatment of refractory erectile dysfunction; however, current literature to aid surgeons on how best to counsel patients on their postoperative inflated penile length is lacking. The aim of this study was to identify preoperative parameters that could better predict postoperative penile length following insertion of an IPP. Twenty men were enrolled in a prospective study examining penile lengths before and after IPP surgery. Patients with Peyronie's disease were excluded from this analysis. Baseline preoperative characteristics, including body mass index, history of hypertension, diabetes, Sexual Health Inventory for Men scores and/or prior radical prostatectomy were recorded. All patients underwent implantation with a three-piece inflatable Coloplast penile prosthesis. We compared stretched penile length to pharmacologically induced erect lengths. Postoperatively, we measured inflated penile lengths at 6 weeks and assessed patients' perception of penile size at 12 weeks. The median (±interquartile range) stretched penile length and pharmacologically induced erect penile length was 15 (±3) and 14.25 (±2) cm, respectively (P=0.5). Median post-prosthesis penile length (13.5±2.13 cm) was smaller than preoperative pharmacologically induced length (P=0.02) and preoperative stretched penile length (P=0.01). The majority of patients (70%) had a decrease in penile length (median loss 0.5±1.5 cm); however, this loss was perceptible by 43% of men. Stretched penile length and pharmacologically induced erect penile length were equally good predictors of postoperative inflated length (Spearman's correlation 0.8 and 0.9, respectively). Pharmacologically induced erect penile length and stretched penile lengths are equal predictors of post-prosthesis penile length. The majority of men will experience some decrease in penile length following prosthesis implantation; however <50% report a subjective loss of penile length.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pênis
/
Ereção Peniana
/
Prótese de Pênis
/
Disfunção Erétil
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Aged
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Int J Impot Res
Ano de publicação:
2014
Tipo de documento:
Article