Measurements of gamma dose and thermal neutron fluence in phantoms exposed to a BNCT epithermal beam with TLD-700.
Gambarini, G; Magni, D; Regazzoni, V; Borroni, M; Carrara, M; Pignoli, E; Burian, J; Marek, M; Klupak, V; Viererbl, L.
Afiliação
  • Gambarini G; Physics Department, Università degli Studi di Milano, via Celoria 16, Milano 20133, Italy INFN, Section of Milan, via Celoria 16, Milano 20133, Italy grazia.gambarini@mi.infn.it.
  • Magni D; Physics Department, Università degli Studi di Milano, via Celoria 16, Milano 20133, Italy.
  • Regazzoni V; Physics Department, Università degli Studi di Milano, via Celoria 16, Milano 20133, Italy.
  • Borroni M; Medical Physics Unit, Fondazione IRCCS Istituto Nazionale Tumori, via Venezian 1, Milano 20133, Italy.
  • Carrara M; Medical Physics Unit, Fondazione IRCCS Istituto Nazionale Tumori, via Venezian 1, Milano 20133, Italy.
  • Pignoli E; Medical Physics Unit, Fondazione IRCCS Istituto Nazionale Tumori, via Venezian 1, Milano 20133, Italy.
  • Burian J; Department of Neutron Physics, Research Centre Rez, Ltd., Rez, Czech Republic.
  • Marek M; Department of Neutron Physics, Research Centre Rez, Ltd., Rez, Czech Republic.
  • Klupak V; Department of Neutron Physics, Research Centre Rez, Ltd., Rez, Czech Republic.
  • Viererbl L; Department of Neutron Physics, Research Centre Rez, Ltd., Rez, Czech Republic.
Radiat Prot Dosimetry ; 161(1-4): 422-7, 2014 Oct.
Article em En | MEDLINE | ID: mdl-24435913
ABSTRACT
Gamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC. The thermal neutron calibration is not simple, because of the impossibility of having thermal neutron fields without gamma contamination, but a calibration method is here proposed, strictly bound to the method itself of dose separation.