Your browser doesn't support javascript.
loading
Ensuring good quality RNA for quantitative real-time PCR isolated from renal proximal tubular cells using laser capture microdissection.
Yee, Jie Yin; Limenta, Lie Michael George; Rogers, Keith; Rogers, Susan Mary; Tay, Vanessa S Y; Lee, Edmund J D.
Afiliação
  • Yee JY; Department of Pharmacology, Yong Loo Lin School of Medicine, National University of Singapore, MD11 10 Medical Drive #05-09, Singapore 117597, Singapore. phcyjy@nus.edu.sg.
BMC Res Notes ; 7: 62, 2014 Jan 27.
Article em En | MEDLINE | ID: mdl-24467986
ABSTRACT

BACKGROUND:

In order to provide gene expression profiles of different cell types, the primary step is to isolate the specific cells of interest via laser capture microdissection (LCM), followed by extraction of good quality total RNA sufficient for quantitative real-time polymerase chain reaction (qPCR) analysis. This LCM-qPCR strategy has allowed numerous gene expression studies on specific cell populations, providing valuable insights into specific cellular changes in diseases. However, such strategy imposed challenges as cells of interests are often available in limited quantities and quality of RNA may be compromised during long periods of time spent on collection of cells and extraction of total RNA; therefore, it is crucial that protocols for sample preparation should be optimised according to different cell populations.

FINDINGS:

We made several modifications to existing protocols to improve the total RNA yield and integrity for downstream qPCR analyses. A modified condensed hematoxylin and eosin (H&E) staining protocol was developed for the identification of rat renal proximal tubular cells (PTCs). It was then determined that a minimal of eight thousands renal PTCs were required to meet the minimal total RNA yield required for downstream qPCR. RNA integrity was assessed using at every progressive step of sample preparation. Therefore, we decided that the shortened H&E staining, together with microdissection should be performed consecutively within twenty minutes for good quality for gene expression analysis. These modified protocols were later applied on six individual rat samples. A panel of twenty rat renal drug transporters and five housekeeping genes showed Ct values below thirty-five, confirming the expression levels of these drug transporters can be detected.

CONCLUSIONS:

We had successfully optimized the protocols to achieve sufficient good quality total RNA from microdissected rat renal PTCs for gene expression profiling via qPCR. This protocol may be suitable for researchers who are interested in employing similar applications for gene expression studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: RNA / Perfilação da Expressão Gênica / Microdissecção e Captura a Laser / Reação em Cadeia da Polimerase em Tempo Real / Túbulos Renais Proximais Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: BMC Res Notes Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: RNA / Perfilação da Expressão Gênica / Microdissecção e Captura a Laser / Reação em Cadeia da Polimerase em Tempo Real / Túbulos Renais Proximais Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: BMC Res Notes Ano de publicação: 2014 Tipo de documento: Article