Your browser doesn't support javascript.
loading
Albumin adsorption onto surfaces of urine collection and analysis containers.
Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg.
Afiliação
  • Robinson MK; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control & Prevention, Atlanta, GA, United States.
  • Caudill SP; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control & Prevention, Atlanta, GA, United States.
  • Koch DD; Grady Memorial Hospital and Emory University, Department of Pathology & Laboratory Medicine, Atlanta, GA, United States.
  • Ritchie J; Emory University, Department of Pathology & Laboratory Medicine, Atlanta, GA, United States.
  • Hortin G; Quest Diagnostics, Cincinnati, OH, United States.
  • Eckfeldt JH; University of Minnesota, Department of Laboratory Medicine and Pathology Minneapolis, MN, United States.
  • Sandberg S; Laboratory of Clinical Biochemistry, Haukeland University Hospital and the Norwegian Quality Improvement of Primary Care Laboratories, Bergen, Norway.
  • Williams D; Division of Diabetes Translation, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control & Prevention, Atlanta, GA, United States.
  • Myers G; American Association for Clinical Chemistry, Washington, DC, United States.
  • Miller WG; Virginia Commonwealth University, Department of Pathology, Richmond, VA, United States. Electronic address: gmiller@vcu.edu.
Clin Chim Acta ; 431: 40-5, 2014 Apr 20.
Article em En | MEDLINE | ID: mdl-24513540
BACKGROUND: Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. METHODS: We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. RESULTS: Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. CONCLUSIONS: Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators.