Your browser doesn't support javascript.
loading
Evaluation of apparent fracture toughness of articular cartilage and hydrogels.
Xiao, Yinghua; Rennerfeldt, Deena A; Friis, Elizabeth A; Gehrke, Stevin H; Detamore, Michael S.
Afiliação
  • Xiao Y; Chemical and Petroleum Engineering, University of Kansas, Lawrence, KS, USA.
  • Rennerfeldt DA; Chemical and Petroleum Engineering, University of Kansas, Lawrence, KS, USA.
  • Friis EA; Mechanical Engineering, University of Kansas, Lawrence, KS, USA.
  • Gehrke SH; Chemical and Petroleum Engineering, University of Kansas, Lawrence, KS, USA.
  • Detamore MS; Chemical and Petroleum Engineering, University of Kansas, Lawrence, KS, USA.
J Tissue Eng Regen Med ; 11(1): 121-128, 2017 01.
Article em En | MEDLINE | ID: mdl-24700577
Recently, biomaterials-based tissue-engineering strategies, including the use of hydrogels, have offered great promise for repairing articular cartilage. Mechanical failure testing in outcome analyses is of crucial clinical importance to the success of engineered constructs. Interpenetrating networks (IPNs) are gaining more attention, due to their superior mechanical integrity. This study provided a combination testing method of apparent fracture toughness, which was applied to both articular cartilage and hydrogels. The apparent fracture toughnesses of two groups, hydrogels and articular cartilage, were evaluated based on the modified single-edge notch test and ASTM standards on the single-edge notch test and compact tension test. The results demonstrated that the toughness for articular cartilage (348 ± 43 MPa/mm½ ) was much higher than that for hydrogels. With a toughness value of 10.8 ± 1.4 MPa/mm½ , IPNs of agarose and poly(ethylene glycol) diacrylate (PEG-DA) looked promising. The IPNs were 1.4 times tougher than PEG-DA alone, although still over an order of magnitude less tough than cartilage. A new method was developed to evaluate hydrogels and cartilage in a manner that enabled a more relevant direct comparison for fracture testing of hydrogels for cartilage tissue engineering. Moreover, a target toughness value for cartilage of using this direct comparison method has been identified (348 ± 43 MPa/mm½ ), and the toughness discrepancy to be overcome between hydrogels and cartilage has been quantified. Copyright © 2014 John Wiley & Sons, Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Materiais Biocompatíveis / Cartilagem Articular / Engenharia Tecidual Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: J Tissue Eng Regen Med Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Materiais Biocompatíveis / Cartilagem Articular / Engenharia Tecidual Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: J Tissue Eng Regen Med Ano de publicação: 2017 Tipo de documento: Article